Support Center > Search Results > SecureKnowledge Details
R80.40 SmartConsole Releases Technical Level
Solution
Show the Entire Article

Availability | List of resolved issues | Installation instructions | Revision History

 

Introduction

R80.40 SmartConsole releases accumulate GUI client fixes for R80.40.

The below list describes each resolved issue and provides the Build number, in which the fix was included. All resolved issues are included in the Incremental SmartConsole Build starting from the Build number listed in this table (inclusive). In addition, you can find the date when the Build was published.

Unless stated otherwise, every R80.40 SmartConsole Build in this article including R80.40 GA SmartConsole build can be used as a GUI client for each R80.40 Jumbo Hotfix Take and for R80.40 General Availability.

The Incremental SmartConsole Builds table and this article are periodically updated.

Availability

  • General Availability Build

    Build Date SmartConsole package
    423 25 April 2021 (EXE)
    • For R80.40 Portable SmartConsole, refer to sk116158.

    • For R80.40 SmartConsole for SandBlast Agent, refer to sk164415.

    Note: Starting from Build 396, all R80.40 SmartConsole Builds are aligned to be higher than R80.40 SmartConsole GA Build 394 released on Jan 28th 2020.



List of Resolved issues per Build

ID Description
SmartConsole - General Availability Build 423 (25 April 2021)
PRJ-24678,
PRJ-21304
NEW: Added support for SAML authentication method for Remote Access VPN. Refer to sk172909 for configuration instructions.
  • Requires R80.40 Jumbo Hotfix Accumulator Take 114 (or higher).
PRJ-21286,
CIS-3221
NEW: When connecting to incompatible server version and the compatible SmartConsole is not installed, user can download the installation package from the login screen.
PRJ-21687,
PMTR-64410
NEW: Added the "Verify Access Policy" action to the Access Policy toolbar Actions menu.
PRJ-21803,
PMTR-64039
SmartConsole title and borders for some windows may become transparent after upgrade to Windows10 build 20h2.
PRJ-21204,
PRHF-13623
In some scenarios, adding the '#' symbol in the "End-User Agreement Settings" form under Identity Awareness may cause the Threat-Prevention Policy installation to fail.
PRJ-22606,
PRHF-15743
The diffServ properties are missing from the Express QoS configuration page in SmartConsole.
PRJ-14735,
PRHF-11878
In some scenarios, the protection name for IPS static protections is not visible on the log card.
PRJ-10356 In rare scenarios, the "Publish" operation performed by one administrator may cause the SmartConsole of another administrator to unexpectedly close.
SmartConsole - General Availability Build 422 (17 March 2021)
PRJ-20352,
CIS-3177
NEW: When the user connects with an incompatible client version to the server, he will automatically launch the correct SmartConsole version installed on his computer. Refer to sk171422.
PRJ-20579,
PMTR-62932
UPDATE:
  • Allow read-only users to generate a Compliance Regulation report.
  • Display Best Practices' information on the Regulation report.
  • For a selected Best Practice, allow activating/deactivating multiple relevant objects at the same time.
PRJ-20404 In some scenarios, SmartConsole web extension does not load correctly in environments where proxy is defined.
PRJ-21815,
PRHF-15236
When uploading Endpoint Client with SmartConsole R80.40 Build 415, the action may fail with message "This version of Smart Endpoint is not compatible with the uploaded client. Creating a recovery media for this client might now be possible. Do you wish to upload the client anyway?"
PRJ-20622,
PRHF-14751
When moving Endpoints from SmartEndpoint Reporting tab to a virtual group after scrolling down the list, not all endpoints are moved.
PRJ-20815,
PRHF-14460
In some scenarios, a wrong value for 'Any' is displayed when adding an exception in the Inspection Settings view.
SmartConsole - General Availability Build 416 (31 January 2021)
PRJ-15504,
PMTR-57285
UPDATE: Removed the "Scan priority will be lower than other running processes" option from SmartEndpoint.
PRJ-20215,
PMTR-19017
In some scenarios, when a user attempts to delete a VSX Gateway / VSX Cluster, the "Server error is: Failed to remove/detach objects licenses" error message appears and the operation may not be completed successfully. Refer to sk167492.
  • Requires R80.40 Jumbo Hotfix Accumulator Take 92 (or higher).
PRJ-20262,
PMTR-61134
"N/A" is displayed instead of "Any" in the Protection drop-down menu under
Inspection Settings -> Core Protections -> Exception editor window.
PRJ-12507,
PMTR-51902
Export of dynamic package may fail if the folder destination name is written in a non-English language. 
PRJ-20511,
PRHF-13866
In rare scenarios, legacy SmartDashboard may unexpectedly close upon loading.
PRJ-20465,
PRHF-14559
In some scenarios, after search in Access policy, Hitcount shows incorrect information.
SmartConsole - General Availability Build 415 (16 December 2020)
PRJ-18593,
PRJ-18307
NEW:
  • Added support for 1570R, 1600 and 1800 SMB Appliances.
  • Added support for Threat Emulation blade on LSM profile of R80.20 SMB gateways and clusters.

  • Requires R80.40 Jumbo Hotfix Accumulator Take 91 (or higher).
PRJ-18856,
PRJ-17805
NEW: Added IoT support on Multi-Domain Security Management.
  • Requires R80.40 Jumbo Hotfix Accumulator Take 91 (or higher).
PRJ-18571,
PMTR-59637
UPDATE: Added ability to select 'Any' in the Service column when creating a custom firewall Best practice.
  • Requires R80.40 Jumbo Hotfix Accumulator Take 91 (or higher).
PRJ-18052,
PRHF-13479
In some scenarios, when hovering quickly between objects in SmartConsole, the tooltip shows incorrect information.
PRJ-17048,
PRHF-12932
In some scenarios, in the IPS Core Protections -> Exceptions view, the default protection appears as (object id ; "Any") .
PRJ-18505,
PMTR-61123
In large environments, SmartConsole may disconnect due to timeouts when the user edits a large network group.
PRJ-18228,
PRHF-13552
When there are many gateways and servers defined in a policy and the administrator needs to scroll up and down to see them all, the links in the “Recommended Updates” column ("GATEWAYS & SERVERS” view) may jump to another row.
PRJ-18260,
PRHF-13471
In some scenarios, when searching for logs per rule, the “Not Type session" filter is added automatically to the end of the query.
PRJ-13992,
PMTR-20576
In rare scenarios, SmartConsole unexpectedly closes when opening a log or navigating inside a log card to previous/next log in the results list.
PRJ-18486,
PMTR-58933
In some scenarios, switching to "GATEWAYS & SERVERS" view in CMA context shows the object view instead of switching to the "GATEWAYS & SERVERS" tab.
PRJ-19103,
PMTR-61355
In SmartConsole Demo Mode, some pages may display an "ERR_CONNECTION_REFUSED" error message.
PRJ-20036,
PRJ-19376
In a rare scenario, when user clicks on Mail Transfer Agent (MTA) options in the Security gateway settings or on 'Next hop' column inside MTA settings, SmartConsole shows "Not Responding" and freezes. Refer to sk161232.
  • Requires R80.40 Jumbo Hotfix Accumulator Take 91 (or higher).
SmartConsole - General Availability Build 414 (11 November 2020)
PRJ-17126,
PRJ-16283
NEW: Added ability for administrators to view, add, and delete licenses directly from SmartConsole.
  • Requires R80.40 Jumbo Hotfix Accumulator Take 87 (or higher).
PRJ-14436 NEW: Added ability to enable developer protection feature.
  • Requires R80.40 Jumbo Hotfix Accumulator Take 87 (or higher).
PRJ-18416,
PMTR-59761
UPDATE: Removed all exe files from data/util library and the old cpm_dir (Legacy demo).
PRJ-16372,
PMTR-54228
Adding LSM Small Office Appliance Cluster via LSMcli may cause the SmartProvisioning application to unexpectedly close when navigating to Topology tab in SmartLSM Security Cluster window.
PRJ-16350,
PMTR-58228
In some scenarios, the "Choose Devices" page in the SmartProvisioning Wizard does not show any devices when the user chooses any type of device.
PRJ-13486,
PRHF-11377
In some scenarios, Network Objects are missing in Implied Rule for Mail Transfer Agent.
  • Requires R80.40 Jumbo Hotfix Accumulator Take 87(or higher).
PRJ-17132,
PRHF-13005
When scrolling or clicking on a rule, some inline layer rules may open unexpectedly.
PRJ-17922,
PMTR-60559
In Global Properties under Stateful Inspection tab, the "TCP end timeout (R80.20 and higher gateways)" option does not support values higher than 60 seconds.
  • Requires R80.40 Jumbo Hotfix Accumulator Take 87 (or higher).
PRJ-17293,
PRHF-13082
SmartConsole may unexpectedly close when clicking the license information link under "Licenses" tab of a cluster object on a Multi-Domain Management.
PRJ-14219,
PRHF-8931
When creating a new gateway interface via SmartConsole and click "Get interfaces without the topology", new interfaces are visible. The first interface in the list "bond.0" is marked as edited.
PRJ-14065,
PRHF-10886
In some scenarios, the "Content" column does not appear in the Access policy view even if the Content Awareness blade is on one of its inline-layers.
PRJ-16410,
PMTR-58447
Opening Network Interface Topology Settings dialog in read only mode may lock the Network Interface object.
PRJ-16690,
PRHF-11973
"Auto Refresh" removes the filter from SmartEndpoint Deployment Status Report after refresh. Refer to sk168232.
PRJ-15955 Improved the SmartConsole session hijacking prevention mechanism. 
PRJ-17255,
PMTR-59682
When the mouse hovers on the Custom Application Group, “Error:Loading failed” may pop up.
PRJ-17347,
PMTR-59692
In some scenarios, SmartConsole may unexpectedly close when the user navigates to the Package Repository page. 
PRJ-16758,
PRHF-12703
In some scenarios, it may not be possible to select users for FDE Remote Help with a mouse click/enter in SmartEndpoint. 
PRJ-15617,
PRHF-12247
SmartEndpoint may close without any errors when the user logs in using AD authentication and the username includes spaces or dots. Refer to sk168197.
SmartConsole - General Availability Build 412 (05 November 2020)
The content of Build 412 is identical to the content of Build 411. All planned content of Build 412 was added to Build 414.
SmartConsole - General Availability Build 411 (04 October 2020)
PRJ-12737,
PMTR-53778
In some scenarios, an OPSEC Application editor may work slower than expected or freeze in environments with a very large number of network objects.
PRJ-14349,
PMTR-48486
Opening the "Mobile Access" tab in SmartConsole directs to the "DLP" tab in SmartDashboard.
PRJ-14499,
PRHF-11763
When connecting through SmartConsole for the first time,  the fingerprint message is not suitable for Multi-Domain System. Refer to sk167980.
PRJ-15866,
PMTR-56103
In a rare scenario, the Group Services tooltip shows incorrect information.
PRJ-7998,
PRHF-7031
A new user registration key for certificate enrollment may fail to open if the expiry value for user certificates is set to 1 in Global Properties. Refer to sk163872.
PRJ-16887,
PMTR-56990
R80.40 SmartConsole Build 407 shows empty list of scan policies in Gateway Properties –> Mobile Access –> Endpoint Compliance Settings. Refer to sk169095.
SmartConsole - General Availability Build 410 (26 August 2020)
PRJ-12401,
PRHF-10471
It is not possible to view logs in Install Policy Presets view, if the selected policy name contains spaces or "slash" characters.
PRJ-13759,
PMTR-49523
In SmartConsole's localized language versions (non-English), scrolling a long list of objects in the objects explorer may cause SmartConsole to unexpectedly close.
SmartConsole - General Availability Build 407 (27 July 2020)
PRJ-13113,
PMTR-38599
UPDATE: Do not  use the Sticky Decision Function checkbox for ClusterXL Load Sharing. Use the ccl_force_sticky parameter instead. For more information, see sk162637.
PRJ-12217,
PMTR-52075
In a rare scenario, SmartConsole freezes when double-clicking the Identity Provider object. Refer to sk166434.
PRJ-12593,
PRHF-10662
When attempting to modify the "Default Time Frame" or “Custom time zone” options in the query settings of log view in Logs and Monitor tab, the list of values is presented in be background and the new value cannot be selected.
PRJ-11522,
PMTR-54898
Login with CAPI certificate may cause SmartConsole to unexpectedly close.
PRJ-13328,
PMTR-51061
In high latency environments, the rulebase may get locked if the user tries to rename a rule soon after it was added.
SmartConsole - General Availability Build 398 (15 June 2020)
PRJ-10567,
PMTR-51246
NEW: SmartConsole default login timeout was increased.
PRJ-12034,
PRHF-10274
SmartEndpoint may display an error when administrator navigates to the "Packages For Export" tab.
PRJ-12874,
PMTR-53909
An incorrect netmask may be shown for Virtual System objects in the network group editor.
PRJ-12085,
PRHF-10297
When configuring "Visitor Mode" in SmartConsole and choosing the IP address, the wrong IP address may be displayed after clicking "OK".
PRJ-9735,
EPS-25084
The SmartConsole utility's Reconnect Tool may show the "MSVCP140.dll is missing" message.
PRJ-12301,
PRHF-10335
In some scenarios, inline layers are not shown when searching within the Access policy.
SmartConsole - General Availability Build 396 (10 May 2020)
PRJ-11012 NEW: Added support for Check Point 3800, 6400, 6700, 7000, 16200, 16600HS, 28000 and 28600HS appliances. Refer to sk110052, sk139932 and sk152733.
  • Requires R80.40 Jumbo Hotfix Accumulator Take 45 (or higher).
SmartConsole - General Availability Build 40 (26 April 2020)
PRJ-9506,
CIS-2162
NEW: Added section in SmartConsole.exe.config that allows defining the per-server custom connection ports for FWM and CPM
PRJ-9503,
PMTR-49896
NEW: Added a list item count inside the User Group, Network Group and Service Group editors. The item count supports only one level of nesting. If a group includes another group, only one object is counted (users, network and services from the nested group are not counted).
PRJ-10727,
PMTR-51445
In some scenarios, it is not possible to enable the Threat Emulation blade for a Security gateway.
PRJ-10291,
PRJ-134
In some scenarios, SmartConsole may unexpectedly close when trying to update statuses of the Compliance Best Practices and generating new alerts.
PRJ-11067,
PMTR-50930
In a rare scenario, SmartConsole may unexpectedly close after stopping the SmartConsole diagnostics service.
PRJ-10468,
PMTR-50086
A certificate in the Certificate column of the HTTPS Inspection Policy cannot be removed by selecting it and hitting the delete key on the keyboard. The number of changes made in the session increments by one but the certificate remains in the column. 
PRJ-9981,
PRHF-7813
After overriding the logging or the Packet Capture option for an IPS protection, the protection may be shown as disabled. This is only a display issue.
SmartConsole - General Availability Build 19 (16 March 2020)
PRJ-9509 In a rare scenario, SmartConsole may unexpectedly close when closing a window of Revert to Revision, Central Deployment, Infinity Threat Prevention or a window hosting an extension (like Changes Report).
PRJ-9353,
MPTT-1812
In a rare scenario, SmartConsole may unexpectedly close when scrolling in the rulebase or navigating to a rule.
PRJ-9386,
PRHF-8036
In some scenarios, the Menu option to view or edit cluster member object on Multi-Domain's gateways view does not show the correct data.
PRJ-8702,
PRHF-7991
The shared secret's edit button may be grayed out.
PRJ-10167 While in Multi-Session mode, SmartConsole may not display the "Recent Sessions" menu.
PRJ-8840,
CIS-2698
In high latency environments, hovering over the Access Policy to view a tooltip may cause the user interface to freeze for a few seconds.
PRJ-9274,
PMTR-48598
After selecting a rule with an inline layer and then selecting a "simple" rule, the action may be missing from the rule summary.

 

Installation instructions

Procedure:

  • Show / Hide instructions for Manual SmartConsole clients installation

    Note: uninstall prior SmartConsole clients Build before installing the new one.
    • To install the SmartConsole clients on Windows platforms:

      1. Download the SmartConsole application build package from the table above.

      2. Run the SmartConsole executable.

      3. Continue with the instructions on the screen.

    To install SmartConsole silently, perform:

    1. Download the SmartConsole application package from the table above and extract it into temporary folder, for example C:\TEMP-SC

    2. Go to this temporary folder: cd C:\TEMP-SC

    3. For silent installation, run: C:\TEMP-SC\SmartConsole.exe /s
      Note: SmartConsole will be installed into its default location.



  • Show / Hide instructions for SmartConsole clients installation using CPUSE


Revision History

Show / Hide revision history

Date Description
25 Апр 2021 Released SmartConsole Build 423
17 Mar 2021 Released SmartConsole Build 422
31 Jan 2021 Released SmartConsole Build 416
16 Dec 2020 Released SmartConsole Build 415
11 Nov 2020 Released SmartConsole Build 414
05 Nov 2020 Released SmartConsole Build 412
04 Oct 2020 Released SmartConsole Build 411
26 Aug 2020 Released SmartConsole Build 410
27 July 2020 Released SmartConsole Build 407
01 Jul 2020 Added PRJ-12034 to Build 398
15 Jun 2020 Released SmartConsole Build 398
10 May 2020 Released SmartConsole Build 396
26 Apr 2020 Released SmartConsole Build 40
16 Mar 2020 First release of this document - R80.40 SmartConsole Build 19

Give us Feedback
Please rate this document
[1=Worst,5=Best]
Comment